TB-FordPMGR

Attention !
Ford, Lincoln, Mercury and Mazda owners.


To reduce the risk of premature starter failure these steps must be followed.

Applications equipped with Motorcraft PMGR
starters have a no start problem that usually occurs
because of a bad ground or due to corrosion at the
ignition terminal of the starter solenoid. Your starter was
originally equipped with a male spade type connector
which is not protected from the elements thus creating
corrosion and a poor connection.

Ford Motor Company has recognized this as a
problem. A conversion kit was produced to change
the original spade connector to an eyelet/post type
connection. This provides better current carrying
capabilities and is more corrosion resistant.


Installation
To install the ignition wire onto the new starter cut 4-5 inches off of your existing
ignition wire harness ( this is where the corrosion exists ). Strip 3/8 inch of the
insulation off the ignition wire. Ensure that the exposed copper wire is clean and
shiny. Insert this wire into the butt connector and crimp using a proper crimping tool.
Do not remove the plastic protection insulator surrounding the butt connector. After
crimping the wire into the connector heat the butt connector insulation until it
conforms to the ignition wire. When you heat this connection the insulator melts
around the wire creating a weatherproof connection

TBFordPMGR (Rev 01) Publictech, Inc. 2000